Currently Enacted Building Codes

  • 2016 California Administrative Code;
  • 2016 California Building Code, Volumes 1 and 2, Chapters 1 through 26, 31, Section 3109, and incorporating Appendix H, Signs, and Appendix I, Patio Covers;
  • 2016 California Residential Code, Chapters 1 through 10, and including Appendix E, Manufactured Housing Used as Dwellings, , Appendix H, Patio Covers, and Appendix V, Swimming Pool Safety Act
  • 2016 California Electrical Code, including Informative Annex Chapters A, B, C and D; Based on the 2014 NEC
  • 2016 California Mechanical Code, including Appendix Chapters A, B and C; Based on the 2015 UMC
  • 2016 California Plumbing Code, including Appendix Chapters A, B, D and I; based on the 2015 UPC
  • 2016 California Energy Code, including Appendix Chapters;
  • 2016 California Historical Building Code, including Appendix Chapters;
  • 2016 California Existing Building Code, including Appendix Chapters;
  • 2016 California Fire Code based on the 2015 IFC,
  • 2016 California Green Building Standards Code, Chapters 1 through 8;
  • 2016 California Referenced Standards Code, including Appendix Chapters;
  • Uniform Housing Code, 1997 Edition, as published by the International Conference of Building Officials;
  • The Uniform Code for the Abatement of Dangerous Buildings, 1997 Edition, as published by the International Conference of Building Officials
Snow Loads: Ground Snow Load - Zero

Wind Loads: Ultimate Wind Speed: 1 & 2 Family Dwellings/ 85 mph; Risk Category I/ 100 mph; Risk Category II/ 110 mph; Risk Category III & IV/ 115 mph Exposure Category Central Turlock: B (Minimum 1/2 Mile from City Limits or open areas) When not considered Central Turlock utilize exposure category: C.

Rain Loads: 2" per hour

Seismic Loads: Unless otherwise justified by analysis, all buildings and non-building structures within the City limits shall be assigned to Seismic Design Category (SDC) D
In accordance with CBC 1613.3.2, soil Site Class D shall be assumed for all sites unless otherwise justified by a registered design professional and/or geotechnical report.

Soil Bearing Pressure:
  • Allowable Foundation - 1500 psf without a Soils Report
  • Allowable Lateral - 100 psf/ft without a Soils Report
Climate Zone: 12